text.skipToContent text.skipToNavigation

Residual current circuit-breakers 4-pole, 16 A, 0.03 A, Type B+, mobile installation, N left

  1. DOEPKE DFS4 016-4/0,03-B+ MI 2133839
Piece
Residual current circuit-breakers (RCCB) switch the power supply off if dangerous high residual currents occur. DFS 4 are two-terminal or two-terminal pair residual current circuit-breakers for single- or three-phase networks. In the standard design, the compact devices are just four module widths wide. The compact residual current circuit-breakers are available with a number of different types of residual currents and versions at rated currents up to 125 A. The large two-tier terminals can also accommodate large conductor cross-sections. A practical multifunction switch toggle simplifies troubleshooting. They can be provided with pre-prepared labels using free-of-charge software. Type B+ residual current circuit-breakers are AC-DC sensitive. They protect against pulsating and AC residual currents, residual currents with mixed frequencies and smooth DC residual currents. They seamlessly detect residual currents in all frequencies up to 20 kHz with a maximum tripping threshold of 420 mA. The switches therefore provide better fire protection. MI version AC-DC sensitive residual current circuit-breakers for mobile installation can easily be fitted downstream of Type A or unknown RCCBs. They are tripped at smooth DC residual currents of 6 mA and safeguard the protective function of upstream RCCBs. Devices in the standard design are intended for monitoring circuits with a rated voltage of 230 V/400 V and a rated frequency of 50 Hz. Properties: tripping threshold of 6 mA for smooth DC residual currents; AC/DC sensitive for residual currents with frequencies and mixed frequencies of 0 Hz (smooth direct current) up to 20 kHz; meets the requirements of design regulations VDE 0664-10, VDE 0664-400, ÖVE/ÖNORM E 8601; electromagnetic compatibility in accordance with VDE 0664-30 and VDE 08396-2 (interference resistance for industrial applications) high availability even of voltage-independent detection of smooth DC residual current and AC residual current with frequencies not equal to 50/60 Hz thanks to full functional compatibility with mains voltages from at least 50 V AC ; mains-voltage-independent tripping when type A residual currents occur; compact design for all rated currents; high short-circuit resistance; double-sided two-tier terminals for large conductor cross-section and busbar; switch position indicator; viewing window for labels; multifunction switch toggle with three positions: "on", "off" and "tripped"; also available in the "HD" design; Neutral conductors with standard design left, for two-terminal-pair devices type A/AC/F up to 125 A and type B/B+ up to 80 A; N-right available at no extra charge.; Mounting: quick fastening to mounting rail; any installation position; supply preferably from above; Application areas: Ideally suited for mobile use in power distributors e.g. for rental equipment, where upstream RCCBs of an unknown type are present. Due to the low DC tripping threshold, the AC-DC sensitive RCCB version MI also can be operated downstream of an RCCB Type A or F.; commercial and industrial and also mobile installations with TT, TN-S and TN-C-S systems, where power electronics equipment is used without galvanic isolation from the mains, e.g. frequency converters, switching power supplies, high-frequency converters. photovoltaic installations and UPS equipment with frequency converters without transformers.; Facilities at risk of fire;