Residual current circuit-breakers 4-pole, 16 A, 0.10 A, Type A, short-time delayed, N left

  1. DOEPKE DFS4 016-4/0,10-A KV 2133850
Piece
Residual current circuit-breakers (RCCB) switch the power supply off if dangerous high residual currents occur. DFS 4 are two-terminal or two-terminal pair residual current circuit-breakers for single- or three-phase networks. In the standard design, the compact devices are just four module widths wide. The compact residual current circuit-breakers are available with a number of different types of residual currents and versions at rated currents up to 125 A. The large two-tier terminals can also accommodate large conductor cross-sections. A practical multifunction switch toggle simplifies troubleshooting. They can be provided with pre-prepared labels using free-of-charge software. Type A switches are sensitive to pulsating and alternating currents. This function is independent of the mains voltage. Residual current circuit-breakers in the KV design have a response delay, so are much less sensitive to brief pulsed fault currents. This enables them to increase system availability. They can effectively be used instead of a standard switch, as their protective function is completely retained. Devices in the standard design are intended for monitoring circuits with a rated voltage of 230 V/400 V and a rated frequency of 50 Hz. Properties: high immunity against surge currents and mains-voltage-operated secondary current impulses; tripping not dependent on mains and auxiliary voltage; sensitive to AC residual currents and pulsating DC residual currents (type A) compact design for all rated currents; high short-circuit resistance; double-sided two-tier terminals for large conductor cross-section and busbar; switch position indicator; viewing window for labels; multifunction switch toggle with three positions: "on", "off" and "tripped"; also available in the "HD" design; Neutral conductors with standard design left, for two-terminal-pair devices type A/AC/F up to 125 A and type B/B+ up to 80 A; N-right available at no extra charge.; Mounting: quick fastening to mounting rail; any installation position; supply from any direction; Application areas: Power supplies to residential and purpose-built building as well as industrial facilities with TN-S, TT and TN-C-S networks, in which conventional RCCBs trip following transient leakage currents and this is not desired, such as in systems with long cable lengths behind the RCCB, lighting systems with lots of fluorescent lamps (<gt/> 20 lamps). computer systems and solar power systems.; Excluded is the application in TN-C systems and for the protection of installations in which electronic equipment could generate smooth DC currents or residual currents with frequencies other than 50 Hz. Comprehensive protection is not provided in this case. For these applications we recommend our AC/DC sensitive residual current circuit-breakers (Type B or B+).;