text.skipToContent
text.skipToNavigation
You searched for "leuze Data overdracht"
-
CML730i-R05-2000.R/PB-M12Operating range: 0.1-4.5 m; Measurement field length: 2.000mm; Beam spacing: 5mm; Cycle time: 4.15 ms; Response time per beam: 10 µs; Supply voltage: 18-30VDC; Interface: PROFIBUS DP; Connection: Connector; M12; Rear sidRead morePrices available after login
-
CML720i-R20-1110.R/PB-M12Operating range: 0.3-7 m; Measurement field length: 1.110mm; Beam spacing: 20mm; Cycle time: 2.08 ms; Response time per beam: 30 µs; Supply voltage: 18-30VDC; Interface: PROFIBUS DP; Connection: Connector; M12; Rear sideRead morePrices available after login
-
CML730i-R05-560.A/PB-M12Operating range: 0.1-4.5 m; Measurement field length: 560mm; Beam spacing: 5mm; Cycle time: 1.27 ms; Response time per beam: 10 µs; Supply voltage: 18-30VDC; Interface: PROFIBUS DP; Connection: Connector; M12; Axial; 8 -Read morePrices available after login
-
CML730i-R05-2960.A/PB-M12Operating range: 0.1-4.5 m; Measurement field length: 2.960mm; Beam spacing: 5mm; Cycle time: 6.07 ms; Response time per beam: 10 µs; Supply voltage: 18-30VDC; Interface: PROFIBUS DP; Connection: Connector; M12; Axial; 8Read morePrices available after login
-
CML720i-R10-2240.A/PB-M12Operating range: 0.3-7 m; Measurement field length: 2.240mm; Beam spacing: 10mm; Cycle time: 7.12 ms; Response time per beam: 30 µs; Supply voltage: 18-30VDC; Interface: PROFIBUS DP; Connection: Connector; M12; Axial; 8 Read morePrices available after login
-
CML730i-R05-2080.R/PB-M12Operating range: 0.1-4.5 m; Measurement field length: 2.080mm; Beam spacing: 5mm; Cycle time: 4.31 ms; Response time per beam: 10 µs; Supply voltage: 18-30VDC; Interface: PROFIBUS DP; Connection: Connector; M12; Rear sidRead morePrices available after login
-
CML730i-R05-1760.A/PB-M12Operating range: 0.1-4.5 m; Measurement field length: 1.760mm; Beam spacing: 5mm; Cycle time: 3.67 ms; Response time per beam: 10 µs; Supply voltage: 18-30VDC; Interface: PROFIBUS DP; Connection: Connector; M12; Axial; 8Read morePrices available after login
-
CML730i-R10-1280.R/PB-M12Operating range: 0.3-9.5 m; Measurement field length: 1.280mm; Beam spacing: 10mm; Cycle time: 1.43 ms; Response time per beam: 10 µs; Supply voltage: 18-30VDC; Interface: PROFIBUS DP; Connection: Connector; M12; Rear siRead morePrices available after login
-
CML720i-R20-2230.R/PB-M12Operating range: 0.3-7 m; Measurement field length: 2.230mm; Beam spacing: 20mm; Cycle time: 3.76 ms; Response time per beam: 30 µs; Supply voltage: 18-30VDC; Interface: PROFIBUS DP; Connection: Connector; M12; Rear sideRead morePrices available after login
-
CML720i-R20-2070.R/PB-M12Operating range: 0.3-7 m; Measurement field length: 2.070mm; Beam spacing: 20mm; Cycle time: 3.52 ms; Response time per beam: 30 µs; Supply voltage: 18-30VDC; Interface: PROFIBUS DP; Connection: Connector; M12; Rear sideRead morePrices available after login
-
CML720i-R10-2560.A/PB-M12Operating range: 0.3-7 m; Measurement field length: 2.560mm; Beam spacing: 10mm; Cycle time: 8.08 ms; Response time per beam: 30 µs; Supply voltage: 18-30VDC; Interface: PROFIBUS DP; Connection: Connector; M12; Axial; 8 Read morePrices available after login
-
CML730i-R05-1520.R/PB-M12Operating range: 0.1-4.5 m; Measurement field length: 1.520mm; Beam spacing: 5mm; Cycle time: 3.19 ms; Response time per beam: 10 µs; Supply voltage: 18-30VDC; Interface: PROFIBUS DP; Connection: Connector; M12; Rear sidRead morePrices available after login
-
CML730i-R10-1120.R/PB-M12Operating range: 0.3-9.5 m; Measurement field length: 1.120mm; Beam spacing: 10mm; Cycle time: 1.27 ms; Response time per beam: 10 µs; Supply voltage: 18-30VDC; Interface: PROFIBUS DP; Connection: Connector; M12; Rear siRead morePrices available after login
-
CML730i-R05-2800.R/PB-M12Operating range: 0.1-4.5 m; Measurement field length: 2.800mm; Beam spacing: 5mm; Cycle time: 5.75 ms; Response time per beam: 10 µs; Supply voltage: 18-30VDC; Interface: PROFIBUS DP; Connection: Connector; M12; Rear sidRead morePrices available after login
-
CML730i-R05-2000.A/PB-M12Operating range: 0.1-4.5 m; Measurement field length: 2.000mm; Beam spacing: 5mm; Cycle time: 4.15 ms; Response time per beam: 10 µs; Supply voltage: 18-30VDC; Interface: PROFIBUS DP; Connection: Connector; M12; Axial; 8Read morePrices available after login
-
CML720i-R20-470.A/PB-M12Operating range: 0.3-7 m; Measurement field length: 470mm; Beam spacing: 20mm; Cycle time: 1.12 ms; Response time per beam: 30 µs; Supply voltage: 18-30VDC; Interface: PROFIBUS DP; Connection: Connector; M12; Axial; 8 -pRead morePrices available after login
-
CML730i-R05-2880.R/PB-M12Operating range: 0.1-4.5 m; Measurement field length: 2.880mm; Beam spacing: 5mm; Cycle time: 5.91 ms; Response time per beam: 10 µs; Supply voltage: 18-30VDC; Interface: PROFIBUS DP; Connection: Connector; M12; Rear sidRead morePrices available after login
-
CML730i-R05-1760.R/PB-M12Operating range: 0.1-4.5 m; Measurement field length: 1.760mm; Beam spacing: 5mm; Cycle time: 3.67 ms; Response time per beam: 10 µs; Supply voltage: 18-30VDC; Interface: PROFIBUS DP; Connection: Connector; M12; Rear sidRead morePrices available after login
-
CML720i-R20-1910.R/PB-M12Operating range: 0.3-7 m; Measurement field length: 1.910mm; Beam spacing: 20mm; Cycle time: 3.28 ms; Response time per beam: 30 µs; Supply voltage: 18-30VDC; Interface: PROFIBUS DP; Connection: Connector; M12; Rear sideRead morePrices available after login
-
CML730i-R05-320.A/PB-M12Operating range: 0.1-4.5 m; Measurement field length: 320mm; Beam spacing: 5mm; Cycle time: 1 ms; Response time per beam: 10 µs; Supply voltage: 18-30VDC; Interface: PROFIBUS DP; Connection: Connector; M12; Axial; 8 -pinRead morePrices available after login
-
CML720i-R10-960.R/PB-M12Operating range: 0.3-7 m; Measurement field length: 960mm; Beam spacing: 10mm; Cycle time: 3.28 ms; Response time per beam: 30 µs; Supply voltage: 18-30VDC; Interface: PROFIBUS DP; Connection: Connector; M12; Rear side; Read morePrices available after login
-
CML730i-R05-640.R/PB-M12Operating range: 0.1-4.5 m; Measurement field length: 640mm; Beam spacing: 5mm; Cycle time: 1.43 ms; Response time per beam: 10 µs; Supply voltage: 18-30VDC; Interface: PROFIBUS DP; Connection: Connector; M12; Rear side;Read morePrices available after login
-
CML730i-R05-1600.A/PB-M12Operating range: 0.1-4.5 m; Measurement field length: 1.600mm; Beam spacing: 5mm; Cycle time: 3.35 ms; Response time per beam: 10 µs; Supply voltage: 18-30VDC; Interface: PROFIBUS DP; Connection: Connector; M12; Axial; 8Read morePrices available after login
-
CML730i-R05-960.R/PB-M12Operating range: 0.1-4.5 m; Measurement field length: 960mm; Beam spacing: 5mm; Cycle time: 2.07 ms; Response time per beam: 10 µs; Supply voltage: 18-30VDC; Interface: PROFIBUS DP; Connection: Connector; M12; Rear side;Read morePrices available after login
-
CML730i-R05-160.R/PB-M12Operating range: 0.1-4.5 m; Measurement field length: 160mm; Beam spacing: 5mm; Cycle time: 1 ms; Response time per beam: 10 µs; Supply voltage: 18-30VDC; Interface: PROFIBUS DP; Connection: Connector; M12; Rear side; 8 Read morePrices available after login
Added to my shopping cart